Plug-In Serial Interface Module
Cat. No. RZC
ØP
Rated: 120VAC, 60Hz
INStallatIoN INStRuCtIoNS
DI-000-RZC0P-00C
Compatible with
TMenabled products!
WaRNINGS aND CautIoNS:
WaRNINGS aND CautIoNS:
•
•
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult a qualified electrician.
•
Save this instruction sheet. It contains important technical data along with testing
and troubleshooting information which will be useful after installation is complete.
attaching Serial-RS232 Cable
or HaI Cable to Plug-In Serial
Interface Module:
Including Plug-In Serial
Interface Module into Z-WavetM
Network:
Step 1
Step 3
Step 3 cont’d
INtRoDuCtIoN
Leviton’s ViziaTM RF components are designed
to communicate with each other via Radio
Frequency (RF) to provide remote control
of your lighting. Using RF technology allows
Leviton to provide the greatest signal integrity
possible. Each module in Leviton’s ViziaTM
RF component line is a Z-WaveTM enabled
device. In a Z-WaveTM network, each device is
designed to act as a router. These routers will
re-transmit the RF signal from one device to
another until the intended device is reached.
This ensures that the signal is received by its
intended device by routing the signal around
obstacles and radio dead spots. The Plug-in
Serial Interface Module is compatible with any
Z-Wave™ enabled network, regardless of the
manufacturer and can also be used with other
devices displaying the Z-Wave™ logo.
E) The Primary Programmer/Remote will
assign a Home ID, Node ID, and Name for
this device.
NotE: In order to use your ViziaTM Plug-In Serial
Interface Module in a Z-WaveTM network, it must
be Included into the network using a Primary
Programmer/Remote, such as Leviton’s Cat.
No., RZCPG. Before Including your module,
please refer to the Primary Programmer/Remote
instruction sheet for complete information. Refer
to Step 3 for further details.
NotES:
•
If using a non-Leviton Programmer/Remote,
refer to the Programmer/Remote instruction
sheet.
Plug-In Serial Interface Modules included into
a Z-WaveTM network must be updated after you
have included all other devices.
NotE: This information will be stored in the
Programmer/Remote to be used for future
reference.
NotE: You may name or edit the node of
this device at this time.
•
F) the Plug-In Serial Interface Module is
now installed in the network.
G) After all devices are included into the
network, the Plug-In Serial Interface
Module must be updated to allow proper
network function. To update Plug-In Serial
Interface Module proceed as follows:
a) If using a Leviton Z-WaveTM Programmer/
Remote, Cat. No. RZCPG, press the Menu
button and scroll down to System Setup. Press
the center button to select System Setup Menu.
Press the center button to select Network.
Press the center button to <Include Node>.
B) If using RZCPG Programmer/Remote, you will
be prompted to prepare device for inclusion. To
do this you must put the Plug-In Serial Interface
Module into programming mode.
•
Attach RS232 cable to Plug-
In Serial Interface Module
and CPU.
oR
Attach HAI cable to Plug-In
Serial Interface Module and
HAI controller.
•
If using a non-Leviton Programmer/
Remote, refer to the Programmer/
Remote instruction sheet for updating
Plug-In Serial Interface Module.
If using Leviton Z-WaveTM Programmer/
Remote, Cat. No. RZCPG, press the
Menu button and scroll down to System
Setup. Press the center button to select
System Setup Menu. Press the center
button to select Network. Press the
center button to select Update "cntrl".
When prompted, press button on the
Plug-In Serial Interface Module.
Wait until the RZCPG Programmer/
Remote confirms completion. Update
is done.
CautIoN:
C) To access Program mode, press and hold
programming button until the LED turns Amber.
You are now in Programming mode.
•
Remember to exercise good common sense
when using the Timer features of your remote,
especially when scheduling unattended
devices. There can be some unexpected
consequences if not used with care. For
example, an empty coffee pot can be remotely
turned on. If that should happen, your coffee
pot could be damaged from overheating. If an
electric heater is turned on by remote control
while clothing is draped over it, a fire could
result.
RS232 cable
to CPU
NotE: If the LED on the Plug-In Serial
Interface Module turns solid Red while
including, there has been a communication
error.
RS232 cable to
Interface Module
OR
D) While standing close to the Plug-In Serial
Interface Module (approximately 2-5 ft.), press
the center button on the Programmer/Remote
to <Include> device in the network. NotE:
Only one device may be included at any time.
HAI cable
to HAI controller
HAI cable to
•
Interface Module
attaching Plug-In Serial
Interface Module to Wall
Receptacle:
Step 2
NotE: If the Plug-In Serial Interface Module
has been successfully Included in the
network and the user tries to Include it again
without first excluding it from the network, the
controller will retain the first node ID it had
received and ignore the second.
Programmer/Remote
Cat. No. RZCPG
FEatuRES
•
•
•
•
•
•
RS232 - ASCII
Scene capable
Two way communication
RF reliability
Ease of installation – No new wiring
Compatible with other Z-Wave™ enabled
devices
NotE: This product requires the use of
third party software to function, along with a
relatively high level of programming skill.
•
Plug the Plug-in
Serial Interface
Module into wall
receptacle. Verify
that receptacle is
live. If controlled
by a wall switch,
the switch must
be kept oN at all
times.
Menu Button
1
2
3
4
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Center Button
Programming
Button
INStallING YouR INtERFaCE MoDulE
NotE: Use check boxes
when Steps