Leviton Network Router RZCP User Manual

Plug-In Serial Interface Module  
Cat. No. RZC  
ØP  
Rated: 120VAC, 60Hz  
INStallatIoN INStRuCtIoNS  
DI-000-RZC0P-00C  
Compatible with  
TMenabled products!  
WaRNINGS aND CautIoNS:  
WaRNINGS aND CautIoNS:  
To be installed and/or used in accordance with appropriate electrical codes and regulations.  
If you are unsure about any part of these instructions, consult a qualified electrician.  
Save this instruction sheet. It contains important technical data along with testing  
and troubleshooting information which will be useful after installation is complete.  
attaching Serial-RS232 Cable  
or HaI Cable to Plug-In Serial  
Interface Module:  
Including Plug-In Serial  
Interface Module into Z-WavetM  
Network:  
Step 1  
Step 3  
Step 3 cont’d  
INtRoDuCtIoN  
Leviton’s ViziaTM RF components are designed  
to communicate with each other via Radio  
Frequency (RF) to provide remote control  
of your lighting. Using RF technology allows  
Leviton to provide the greatest signal integrity  
possible. Each module in Leviton’s ViziaTM  
RF component line is a Z-WaveTM enabled  
device. In a Z-WaveTM network, each device is  
designed to act as a router. These routers will  
re-transmit the RF signal from one device to  
another until the intended device is reached.  
This ensures that the signal is received by its  
intended device by routing the signal around  
obstacles and radio dead spots. The Plug-in  
Serial Interface Module is compatible with any  
Z-Wave™ enabled network, regardless of the  
manufacturer and can also be used with other  
devices displaying the Z-Wave™ logo.  
E) The Primary Programmer/Remote will  
assign a Home ID, Node ID, and Name for  
this device.  
NotE: In order to use your ViziaTM Plug-In Serial  
Interface Module in a Z-WaveTM network, it must  
be Included into the network using a Primary  
Programmer/Remote, such as Leviton’s Cat.  
No., RZCPG. Before Including your module,  
please refer to the Primary Programmer/Remote  
instruction sheet for complete information. Refer  
to Step 3 for further details.  
NotES:  
If using a non-Leviton Programmer/Remote,  
refer to the Programmer/Remote instruction  
sheet.  
Plug-In Serial Interface Modules included into  
a Z-WaveTM network must be updated after you  
have included all other devices.  
NotE: This information will be stored in the  
Programmer/Remote to be used for future  
reference.  
NotE: You may name or edit the node of  
this device at this time.  
F) the Plug-In Serial Interface Module is  
now installed in the network.  
G) After all devices are included into the  
network, the Plug-In Serial Interface  
Module must be updated to allow proper  
network function. To update Plug-In Serial  
Interface Module proceed as follows:  
a) If using a Leviton Z-WaveTM Programmer/  
Remote, Cat. No. RZCPG, press the Menu  
button and scroll down to System Setup. Press  
the center button to select System Setup Menu.  
Press the center button to select Network.  
Press the center button to <Include Node>.  
B) If using RZCPG Programmer/Remote, you will  
be prompted to prepare device for inclusion. To  
do this you must put the Plug-In Serial Interface  
Module into programming mode.  
Attach RS232 cable to Plug-  
In Serial Interface Module  
and CPU.  
oR  
Attach HAI cable to Plug-In  
Serial Interface Module and  
HAI controller.  
If using a non-Leviton Programmer/  
Remote, refer to the Programmer/  
Remote instruction sheet for updating  
Plug-In Serial Interface Module.  
If using Leviton Z-WaveTM Programmer/  
Remote, Cat. No. RZCPG, press the  
Menu button and scroll down to System  
Setup. Press the center button to select  
System Setup Menu. Press the center  
button to select Network. Press the  
center button to select Update "cntrl".  
When prompted, press button on the  
Plug-In Serial Interface Module.  
Wait until the RZCPG Programmer/  
Remote confirms completion. Update  
is done.  
CautIoN:  
C) To access Program mode, press and hold  
programming button until the LED turns Amber.  
You are now in Programming mode.  
Remember to exercise good common sense  
when using the Timer features of your remote,  
especially when scheduling unattended  
devices. There can be some unexpected  
consequences if not used with care. For  
example, an empty coffee pot can be remotely  
turned on. If that should happen, your coffee  
pot could be damaged from overheating. If an  
electric heater is turned on by remote control  
while clothing is draped over it, a fire could  
result.  
RS232 cable  
to CPU  
NotE: If the LED on the Plug-In Serial  
Interface Module turns solid Red while  
including, there has been a communication  
error.  
RS232 cable to  
Interface Module  
OR  
D) While standing close to the Plug-In Serial  
Interface Module (approximately 2-5 ft.), press  
the center button on the Programmer/Remote  
to <Include> device in the network. NotE:  
Only one device may be included at any time.  
HAI cable  
to HAI controller  
HAI cable to  
Interface Module  
attaching Plug-In Serial  
Interface Module to Wall  
Receptacle:  
Step 2  
NotE: If the Plug-In Serial Interface Module  
has been successfully Included in the  
network and the user tries to Include it again  
without first excluding it from the network, the  
controller will retain the first node ID it had  
received and ignore the second.  
Programmer/Remote  
Cat. No. RZCPG  
FEatuRES  
RS232 - ASCII  
Scene capable  
Two way communication  
RF reliability  
Ease of installation – No new wiring  
Compatible with other Z-Wave™ enabled  
devices  
NotE: This product requires the use of  
third party software to function, along with a  
relatively high level of programming skill.  
Plug the Plug-in  
Serial Interface  
Module into wall  
receptacle. Verify  
that receptacle is  
live. If controlled  
by a wall switch,  
the switch must  
be kept oN at all  
times.  
Menu Button  
1
2
3
4
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
Center Button  
Programming  
Button  
INStallING YouR INtERFaCE MoDulE  
NotE: Use check boxes  
when Steps  
are completed.  
 

La Crosse Technology Clock Radio WT 5120 433 User Manual
La Crosse Technology Weather Radio 512 807 User Manual
Land Pride Snow Blower RBT3584 User Manual
Leica Microscope Magnifier DM500 B User Manual
Lenovo Personal Computer 10097 2566 User Manual
LG Electronics Air Conditioner W182CM TSNO User Manual
Life Fitness Home Gym SU60 User Manual
Makita Planer 1100MJ User Manual
Manitowoc Ice Ice Maker IB00820 User Manual
Microsoft Network Router MN 500 User Manual