362EC Line/
Extension
Module
362EC
Module
Only for use on the Lucent Technologies PARTNER
Endeavor Communications System
7-foot
Line Cords
COMBO
COMBO
Installation Instructions
Important Safety Instructions
!
WARNING:
The following list provides basic safety precautions that should always be followed when using your
telephone equipment:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the equipment.
3. Unplug all telephone connections before cleaning. DO NOT use liquid cleaners or aerosol cleaners. Use a
damp cloth for cleaning.
4. The product should be serviced by (or taken to) a qualified repair center when service or repair work is
required.
5. DO NOT use the product near water, for example, a wet basement location.
6. Never push objects of any kind into the slots or openings as they may touch dangerous voltage points or
short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the
equipment. Doing so may result in serious damage to the components.
7. DO NOT use the telephone to report a gas leak in the vicinity of the leak.
8. The telephone equipment is provided with a three-wire grounding type plug. This is a safety feature. DO NOT
defeat the safety purpose of the grounding type plug. DO NOT staple or otherwise attach the power supply
cord to building surfaces.
!
CAUTION:
DO NOT block or cover the ventilation slots and openings. They prevent the product from overheating. DO
NOT place the equipment in a separate enclosure unless proper ventilation is provided.
Additional Safety Instructions for Installation Personnel
1. Install the equipment to meet all the environmental and electrical requirements listed in the PARTNER
Endeavor Installation Guide.
2. DO NOT install equipment during a lightning storm.
3. DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations.
4. Never touch uninsulated telephone wires or terminals, unless the telephone line has been disconnected at
the network interface.
5. Use caution when installing or modifying telephone lines.
6. The control unit must be securely wall mounted.
Comcode 108272832
June 1998 (Issue 1)
Copyright 1998 Lucent Technologies
All rights reserved
PARTNER is a registered trademark
of Lucent Technologies
Printed in U.S.A.
PARTNER Endeavor Communications System Installation Instructions -
Using a 2-Slot Carrier
IMPORTANT: To add a 362EC module to a PARTNER Endeavor system, the PARTNER Endeavor processor
module must already be mounted on the wall. If it is not, refer to the PARTNER Endeavor Installation Guide for
instructions. Before starting, disconnect the power cord from the power jack in the carrier. Then follow the
instructions below.
362EC
Processor
Module
A) Move the carrier’s On/Off switch to "Off,"
1and unplug the power cord from the wall
outlet. B) To remove the cover, loosen the
screw on lower front of the cover. C) Place
one hand on the handle on the bottom front
of the cover, and place your other hand on
the top of the cover. Gently pull the cover up
and away from the carrier.
A) Verify that the PARTNER Endeavor
3 processor module is in the center slot of the
carrier. In the other slots, from left to right,
install the 362EC modules. B) Align the
module carefully in the appropriate slot, and
push slowly but firmly in the center of the
module until the connectors on the module
lock into place.
Before installing any modules, make sure the
clear, plastic protector has been removed
from the connector area on the rear of each
module. To remove the protector, grasp the
tabs on the ends of the protector and lift.
2
!
CAUTION:
Caution: Do not force the module. If the
module does not insert easily, remove it,
clear any obstruction, and reinsert it
362EC
Module
362EC
Module
362EC
Module
ECS
Proc.
362EC
Module
P
F
T
4
7
10
13
1
4
Line
Jacks
Line
Jacks
5
7
5
6
8
9
11
12
14
15
2
3
6
8
1
9
2
18
19
20
21
10
11
12
3
13
14
15
26
27
28
MUSIC
ON
HOLD
E
X
T
E
N
S
I
10
11
P
F
T
34
22
29
30
12
13
35
36
18
26
34
42
10
O
N
S
42
43
23
COMBO
24
31
14
COMBO
37
38
44
45
COMBO
19
20
27
28
35
36
43
44
25
11
12
32
15
COMBO
COMBO
33
16
39
COMBO
46
COMBO
17
40
47
COMBO
COMBO
41
48
COMBO
49
Extension
Jacks
21
22
29
30
37
38
45
46
13
14
Extension
Jacks
23
31
39
47
15
C
C
C
A) Plug the power cord into a properly
Check the green lights on the fronts of the
A) Label the lines and extension jacks.
4 B) Connect the line and telephone cords to 5 grounded three-prong wall outlet not 6 modules. If a single light is out, power down
controlled by a switch. B) Power up the
control unit by moving the On/Off switch to
the "On" position.
the carrier, then power up the carrier. If
multiple lights are out, power down the
carrier, reseat both modules, then power up
the carrier. If the lights are still out, in the
Continental U.S., call the hotline at
1-800-721-7071. Outside the Continental
U.S., contact your Lucent Technologies
Representative or local Authorized Dealer.
the appropriate jacks on the new module.
C) Route each cord through the hook on the
front of its module. D) Connect the free end
of each phone cord to the modular wall jacks
for system extensions. E) Connect the free
end of each telephone cord to the modular
connecting blocks for system extensions.
F) Gather the line and extension cords
hanging below the hook and twist tie or wire
wrap them. G) Place the bundle of wires in
the indentation on the bottom carrier.
NOTE:
Connect ETR and T/R combination
devices to the last two ports on the
PARTNER Endeavor processor or
362EC module.
A) To replace the carrier’s cover grasp it by
7 its upper edges and hold it squarely over the
carrier. B) Place the cover over the modules
and make sure it fits firmly in place. If it does
not fit, make sure all modules are seated
properly. C) Tighten the screw on the lower
front of the cover.
PARTNER Endeavor Communications System Installation Instructions -
Using a 5-Slot Carrier
IMPORTANT: To add a 362EC module to a PARTNER Endeavor system, using a 5-slot carrier, the PARTNER
Endeavor processor module and carrier must already be mounted on the wall. If it is not, refer to the PARTNER
Endeavor Installation Guide for instructions. Follow the instructions below to install a 362EC expansion module in
the 5-slot carrier.
|