SAFETY SPECIFICATIONS
PLEASE READ ALL INSTRUCTIONS BEFORE USE
2 y e a r g u a r a n t e e
•
•
Always unplug the heater when not in use.
Do not operate any heater with a damaged cord
or plug, or after the heater malfunctions, has been
dropped or is damaged in any manner. Return
the heater to an authorized service facility for
examination.
This product has not been designed for any uses other
than those specified in this booklet.
SAVE THESE INSTRUCTIONS
YOUR HEATER COLUMN
•
•
Do not use the heaters outdoors.
This heater is not intended for use in bathrooms,
laundry areas or similar moist indoor locations.
Never locate the heater where it may fall into a
bathtub or other water containers.
Before first using your new appliance, it is most
important that you read and follow the instruction in this
use and care booklet, even if you feel you are quite
familiar with this type of appliance.
•
•
Do not use this heater in the immediate
surroundings of a bath, a shower or a swimming
pool.
Do not run the power cord under carpeting or
cover the cord with throw rugs, runners or the
like. Arrange the cord away from traffic areas and
where it will not be tripped over.
Do not place the cord over any part of the heater.
Do not plug this heater into an extension lead,
double adapter or power board.
Your attention is drawn particularly to the section dealing
with “IMPORTANT SAFEGUARDS”. Find a place and
keep this booklet handy for future reference.
Your Column Heater is easy and safe to use. It has been
designed to function quietly and safely under normal
circumstances. Read all instructions to ensure safe and
efficient use.
•
•
•
•
Do not operate unless the cord is fully unreeled.
Do not attempt to repair, disassemble or modify
the appliance. There are no user-serviceable parts,
and this will void the 2 year guarantee.
To disconnect the heater, set controls to OFF then
remove the plug from the outlet.
HEATING
The columns or fins are filled with a special oil that
conducts heat to the metal surfaces. These in turn warm
the air around them which gently and silently heats
the room. Be careful because they work under pressure
as the oil inside heats up. Like any electrical appliance,
this product may cause injury or damage property if
used whilst damaged.
•
•
•
To prevent a possible fire, do not block air intakes
or exhausts in any manner.
Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause
an electric shock, fire or could damage the heater.
This heater has hot electrical parts inside. DO NOT
use it in areas where gasoline, paint or flammable
liquids are used or stored.
Use the heater only as described in this booklet.
Any other use is not recommended by the
manufacturer which may cause fire, electric shock
or injury to persons.
Fully remove the power cord from the cord storage
before use. Always uncoil the power cord before
applying power.
This product must always be used AND STORED
in the upright position.
MOUNTING THE FEET
•
•
1.
Place the column heater upside-down on a
scratch-free location, make sure it is stable and will
not fall.
2.
3.
First snap the cord holder onto the front foot.
(Note: the oval concave should be upwards.)
Snap the front foot onto the front cover and then
use two short screws provided to fix the front foot
in place.
•
•
4.
Snap the back foot onto the back cover and then
use two long screws provided to fix the back foot
into place.
Warning: in order to avoid overheating, do not cover
NOTE: After wheels assembled as to above, take the
unit in upright position, if you find unit is not stable on
the ground, you can adjust the two screws on back
wheels.
the heater.
COMPULSORY WARNING
If the supply cord is damaged, the cord must be
replaced by the manufacturer. This Column Heater
is filled with a precise quantity of oil. Repairs requiring
the opening of the oil container are only to be
conducted by the manufacturer or a qualified authorized
service agent who should be contacted if there is an oil
leakage.
WARNING:
Do not operate without feet attached. Operate the heater
only in an upright position (feet on the bottom, controls
on the top), any other position could create a hazardous
situation.
NOTE: After attaching the feet wait at least 15 minutes
for the oil in each fin to setting before using the column
heater.
Disposal of the oil should be in accordance with local
regulations. You should contact your local council to
determine the correct procedure.
The power selecting can be circulated and the red
power pilot light will be on during the heater powered
on.
OPERATION
1.
Before using the heater make sure that it is on a
flat and stable surface. Damage may occur if it is
placed on an incline or decline.
To cancel the manual mode, push the button “power
setting” until the LCD appear “OFF”, the red power pilot
light will be extinguished. Now the unit can be set in
auto mode.
2.
Set all the controls to OFF position, and insert the
plug into a socket-outlet that is well grounded.
Be sure plug fits tightly into outlet. Be sure that
the main power switch is on before operating the
control panel.
3.) SETTING THE AMBIENT TEMPERATURE
3.
Operation for control panel.
Adjust the “+” or “-“ button to the desired ambient
temperature from 5 to 35˚C at any time during
1.) SETTING THE CLOCK
operation. By pushing once the “+” or “-“ button
the temperature (shown on the right side of the display)
will increase or decrease by 1˚C. Keep the button
pressed to move through the temperature in fast mode.
Set the clock to the correct time before using the heater,
proceeding as follows:
Press the button “hour” until the display shows the
hours for the correct time, then release the button.
Press the button “minute” until the display shows the
minutes for the correct time, then release the button.
Whenever you want ot modify hours or minutes during
operation, just proceed as above.
AM
MAX
C
8 :0 0 2 0
Time
Set
Temperature
AM
MAX
This heater has a sensitive temperature detector,
which automatically monitors the current ambient
temperature and switches the unit on to maintain your
chosen temperature.
C
8 :0 0 3 5
Time
Set
Temperature
OFF
NOTE: Do not modify the clock while the heater is
operating in auto mode. To activate the set time, you
must release the button “hour” or “minute” for at least
5 seconds.
If the selected temperature is higher than the actual
room temperature, the appliance will start automatically
and rapidly heat the room until it reaches the selected
temperature. The unit will automatically maintain the
temperature at a constant level.
2.) SETTING THE POWER
4.) USING OF TIMER
The variable power setting determines how fast the
desired temperature is reached. The higher the power
setting, the more energy is used.
The function of the time works only under the setting
manual mode setting. After the unit is powered on in the
manual mode, press the button “timing” one or more
times within 5 seconds to select the timing level, as per
the following sequence:
NOTE:If you want to operate the appliance in manual
mode, press the button “power setting” to activate it.
In this mode, the function of the booking timer will be
invalidated.
0:00h – 0:30h – 0:45h – 1:00h – 2:00h – 4:00h – 8:00h
To set the required power level, proceed as follows:
press the “power setting” button one or more times
within 5 seconds to select the power level, as per the
following sequence:
The timing setting can be circulated as above sequence
and the timing pilot lamp light will be on during the
timing function activation. To cancel the timing, push
the button “timing” until the LCD appears “0:00h” or
push the button “power setting” until the LCD appears
“OFF” and wait for 5 seconds, the yellow timing pilot
light will go out.
AM
MAX AM
MAX
C
C
8 :0 0 3 5 8 :0 0 3 5
MAXIMUM POWER
MEDIUM POWER
AM MAX AM
MAX
C
C
8 :0 0 3 5 8 :0 0 3 5
OFF
MINIMUM POWER
OFF
The operating time has a span of 24 hours. Auto on and
auto off default value is ”00:00”.
c. Auto
Press the button “booking time” until the LCD appears
“AUTO”. This indicates that the auto mode comes into
effect. The yellow timing pilot light now lights up.
During operating in the auto mode, you can use the
“+” button or “-” to set the desired comfort temperature
as described above and the appliance will
automatically switch on or off at the preset time
and automatically maintain the preset comfort
temperature.
5.) ANTI-FREEZE SETTING
Press the “power setting” button and it is recommended
to select the maximum power level. Set the temperature
to 5˚C with the “-“ button. When set this way, the
appliance will switch on automatically only if the room
temperature falls below 5˚C, to prevent freezing at
minimum energy consumption.
NOTE: Do not press the button “power setting” when
operating in the auto mode, this will cancel the function
of “booking timer”.
6.) USING OF BOOKING TIMER
To cancel the function of “booking timer”, press the
button “booking timer” until blank appears and wait for
5 seconds or press the button “power setting”, the
yellow timing pilot light will go out.
NOTE: If you want to operate the appliance in the auto
mode, press the button “booking timer” to activate it.
I In this mode, the function of the timing will be
i invalidated.
NOTE: To keep the heater’s memory programmed,
always leave the heater plugged in at the mains
socket. If the heater looses its electricity supply, e.g.
switched off at the mains socket or in the event of a
power failure, the heater’s programs will be lost, and
the heater will not work until reset.
Press the button “booking timer” one or more times
within 5 seconds to select the booking timing mode, as
per the following sequence:
AM AUTO ON
MAX PM AUTO ON
MAX
C
C
This heater includes an overheat protection system
that shuts off the heater when parts of the heater
are getting excessively hot. Once it occurs, the heater’s
programs will be lost.
8 :3 0 3 5 4 :0 0 3 5
OFF
OFF
AUTO ON
AM AUTO
AUTO OFF
MAX AM
C
MAX
C
To completely shut the heater off, turn the controls and
power to OFF, and remove plug from the socket-outlet.
8 :0 0 3 5 8 :0 0 3 5
OFF
OFF
AUTO
BLANK
The booking timing mode setting can be circulated as
above sequence and the yellow timing pilot light will be
on during the heater operating in auto mode.
a. Auto on
When the LCD shows “AUTO ON”, the unit comes into
auto power on timing state. To select what time you
require the heater to be on, push the button “hour”
and “minute” until your required operating time appears.
b. Auto off
When the LCD shows “AUTO OFF”, the unit comes into
auto power off timing state. To select what time you
require the heater to be off, push the button “hour”
and “minute” until your required operating time appears.
27 Nourse
Avenue Epping
2
Cape Town
P.O. Box 975 Eppindust 7475 South Africa
Tel: +27 21 534 8114 Fax: +27 21 534 8086
Service Centre Share Call: 086 111 5006
w e b : w w w. c r e a t i v e h o u s e w a r e s . c o . z a
|